Instructions
Safe and Easy to Use: Press and hold button. Lightly scan across forehead. Release button, read temperature. Remove protective cap, read instruction manual completely before using.
Contents:
1 Thermometer
9-V Battery
Protective Cap
Users Manual
Easy, and Safe to Use:
Press and hold button
Lightly scan across forehead
Release button
Read temperature
Totally non-invasive system with advanced infrared technology
Accurate temperature with a gentle forehead scan. Quick, consistently accurate measurements
Continually scans for the highest temperature
Beep and LED flashing indicate a rise to a higher temperature, similar to a radar detector
Reading will remain on display for 30 seconds
Accepted for use in major hospitals
Clinically tested for accuracy
Patented software, providing arterial
More accurate than ear - Harvard Medical School study.
At least as accurate as rectal - Hospital for Sick Children study.
A better thermometer for your child - Just ask your pediatrician.
Recommended for the entire family
Professional Technology for Parents - patented Arterial Heat Balance provides the breakthrough:
Gentle stoke of forehead captures naturally emitted heat from skin over temporal artery.
Red LED lights and soft beep indicate correct scan.
Takes 1,000 readings per second, selecting the most accurate.
Arterial Heat Balance computes the correct temperature.
--------------------------------------------------------------------------------
Features:
Clinical Accuracy - Meets ASTM E1965-98 and EN60601-1 standards for electronic and radiation thermometers to the extent applicable to thermometers which measure the surface of the skin over the temporal artery.
Regulatory Approvals - CE Mark to -0197, TUV, Declaration of Conformity-ISO 9003/08.94, NIST certifiable traceable calibrations, UL listed.
Temperature Range - 15.5 to 42˘XC (60 to 107.6˘XF
Operating Environment - 15.5 to 40˘XC (60 to 104˘XF)
Resolution - 0.1˘XC or ˘XF
Response Time - Approximately 0.04 second
Time Displayed on Screen - 30 seconds before automatic shutdown
Battery Life - Approximately 7500 readings
Size - 7.0 in x 1.75 in x 1.25 in (17.8 cm x 4.45 cm x 3.18 cm)
Weight - 4.5 oz (130 grams) including battery
Display Type - High contrast LCD
Construction Method - Impact resistant casing, hermetically sealed sensing system
Storage Range - -4˘XF to 122˘XF (-20˘XC to 50˘XC)
Warranty - 1 Year Warranty (manufacturer)
--------------------------------------------------------------------------------
Temporal Artery Thermometer
The TemporalScanner Thermometer is a totally non-invasive system with advanced infrared technology providing maximum ease of use with quick, consistently accurate measurements. Advanced, patented technology measures temperatures with a gentle stroke across the forehead. The TemporalScanner Thermometer has been clinically tested for accuracy compared to rectal thermometers and temperature sensors inserted in the heart during course of patient treatment and accepted for use in major hospitals, making it the ideal thermometer for use with newborns, infants, children or adults. The TemporalScanner has patented software, providing arterial heat balance. This unique process determines temperature by accurately measuring the balance between the tissues warming from arterial blood and tissues cooling (warming) caused by heat loss (gain) to the environment.
--------------------------------------------------------------------------------
Why take temperature measurements at the skin surface over the temporal artery?
Directly connected to the heart via the carotid artery.
Has the constant blood flow needed for accurate measurement.
Safest, most convenient, and comfortable place to measure temperature.
The best place to measure temperature is the center of the heart, but this can be done only under a doctorˇ¦s supervision. Doctors know that measurement of the blood temperature in a major artery accurately reflects true body temperature. The TemporalScanner Thermometer is designed to measure the temperature of the skin surface over the temporal artery, a major artery of the head.
The temporal artery is connected to the heart via the carotid artery, directly leading from the aorta, the main trunk of the arterial system. It offers constant blood flow. It is the only such artery positioned close enough to the skin surface to provide access needed to take an accurate measurement. It is easy to use because it is ideally located at the front portion of the forehead. The TemporalScanner is easier and gentler to use than other types of measurement devices such as oral, rectal, underarm and in-ear thermometers because it is truly non-invasive.
Exergen© Corporation.
|